Call 08047637923 100% Response Rate

our range

Transient Voltage Surge Suppression System

Our range of products include transient voltage surge suppression system and surge arrester.
Transient Voltage Surge Suppression System

Transient Voltage Surge Suppression System

Rs 3  / PieceGet Best Price
Model Name/NumberTransient Voltage Surge Suppression System
ApplicationCommercial
WarrantyYes
Phaseon
Country of OriginMade in India
To increase a solid toehold in this industry, we are committed to offer a wide array of Transient Voltage Surge Suppression System. The items offered by us help in tackling phenomenal assurance to issues of unwanted components display in the serious fluctuating mains supply. These items are produced utilizing ideal evaluation parts and advanced innovation in synchronization with universal measures. So as to guarantee quality, the whole range is thoroughly inspected on different parameters by our quality controllers.

Features:

  • Rugged construction
  • Durable
  • Compact design

View Complete details

get quote request a call back
  • Surge  Arrester
  • Surge  Arrester
  • Surge  Arrester
  • Surge  Arrester
Surge  Arrester

Surge Arrester

Rs 8  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

PhaseThree Phase
TypeType 2
No.of Poles3P+N
Highest Voltage Potection600V
BrandEaton
Max Discharge Current50 KA
Technical Data Inserts SPCT2-075 SPCT2-135 SPCT2-175 SPCT2-280 SPCT2-335 SPCT2-385 SPCT2-460 Electrical Mechanical coding x x x x x x x Responding time (rate of voltage rise 5 kV/μs) < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns < 25 ns Voltage protection level at nominal discharge current / Uoc Up < 550 V < 800 V < 1.0 kV < 1.4 kV < 1.6 kV < 1.8 kV < 2.2 kV Voltage protection level at 5 kA (8/20) μs Up 400 V 550 V 700 V 1000 V 1200 V 1350 V 1700 V Max. continuous operating voltage UC 75 VAC 135 VAC 175 VAC 280 VAC 335 VAC 385 VAC 460 VAC TOV test value (5 s) UT = UC = UC = UC 350 VAC 415 VAC 415 VAC 580 VAC Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Open circuit voltage Uoc – – – 10 kV 5 kV – – Nominal discharge current (8/20) μs In 15 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA Charge Q at In 0.43 As 0.57 As 0.57 As 0.57 As 0.57 As 0.57 As 0.57 As Specifi c energy at In 3.2 kJ/??? 5.7 kJ/??? 5.7 kJ/??? 5.7 kJ/??? 5.7 kJ/??? 5.7 kJ/??? 5.7 kJ/??? Max. discharge current Imax 30 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA

View Complete details

get quote request a call back

EXPLORE MORE CATEGORIES